18 KW 10Vdc-450Vdc Bidirectional AC DC Converter For Battery Testing Equipment

Basic Information
Place of Origin: China
Brand Name: ANE
Model Number: BTLA-MTS018-180M-01
Minimum Order Quantity: 10
Price: FOB: 5,000 USD~7,000 USD
Packaging Details: Carton
Delivery Time: 30 work days
Payment Terms: T/T, L/C
Supply Ability: 20000 Per month
Isolation Transformer: Support AC And DC Starting Capability: Support
Voltage Range: 10Vdc~450Vdc Rated Current: 180A
Forward And Reverse Switching Time: <10ms Efficiency: ≥92%
Overload Capability: 1.1 Times ≥ 10min, 1.2 Times ≥ 1min Mean Time Between Failure (MTBF): >100000 Hours
Operating Temperature: -20℃~+45℃ Working Humidity: ≤95%RH,no Condensation
Storage Temperature: -40℃~+70℃ Cooling Method: Intelligent Forced Air Cooling
Altitude: <3000m Communication: CAN,RS485,Ethernet,dry Contact
Reactive Power Compensation: Support Protection Level: IP20
Weight: 26kg Size (W*D*H) 430mm*500mm*130mm: 131*465*510mm

DPS(18kW)High Frequency Isolated AC/DC Bidirectional Converter Module For Battery Testing Equipment

18 KW 10Vdc-450Vdc Bidirectional AC  DC Converter For  Battery Testing Equipment 0

This convrter possesses intelligent forward and backward operation, seamless switching functions, can meet the occasion of two-way energy transformation, and has high frequency isolation function, higher security. At the same time, the product is equipped with on-grid/off-grid switching function, and the switching time is not more than 10ms, which can be applied in more occasions.Using the latest optimized hardware design, advanced control algorithm and advanced manufacturing process, the HF isolated bidirectional power supply is specially developed for lithium battery testing equipment, AC and DC analog power supply, feedback electronic load, EV charging and discharging equipment and energy storage equipment. 

 

Features

Technical parameter

AC side parameters

  BTLA-MTS018-180M-01
  • Rated Input Power
 18kW
wiring Three-phase five wire system
voltage range 380Vac±15%
Rated frequency and range45~65Hz(Adaptive 50/60Hz power grid)
Power factor adjustment range±1
THDi≤5%
 

DC side parameters

  BTLA-MTS018-180M-01
  • Rated voltage
 100Vdc
  • Rated current
 180A
Voltage range 10Vdc-450Vdc
Current range ±180A
Voltage accuracy0.1% F.S
  • Current accuracy
0.1% F.S
Voltage limitingYes
  • Current limiting
Yes
 

Basic Characteristics

 Description
AC/DC starting functionYes
Switching time forward and backward≤10ms
  • Peak efficiency
92%
H*W*D131*465*510mm
  • Weight(kg)
26kg
 

Environmental Conditions

  • Operating Temperature Range
°C-20℃~+45℃ 
  • Working humidity range
%RH<+95Relative humidity, non-condensing
Storage temperature°C-40 ~ +55 
  • Storage humidity
%RH0 ~ +95Relative humidity, non-condensing
  • Cooling mode
-
  • Force-air cooling
 
  • Altitude
m3000 
  • Protection grade
-IP20 
  • Noise
dB<70 
 

Communication

Communication mode-
  • CAN,RS485,Ethernet,dry contact
 
Report signal-Various protection signals, voltage and current signals 
Receipt signal-On off signal 
 

 

 